This is a 2 Year Follow up Clinical and Radiographic Analysis of a Novel All Polyethelene Glenoid Component in Standard Total Shoulder Arthroplasty.
Status: | Completed |
---|---|
Conditions: | Osteoarthritis (OA) |
Therapuetic Areas: | Rheumatology |
Healthy: | No |
Age Range: | 40 - 80 |
Updated: | 4/2/2016 |
Start Date: | April 2011 |
End Date: | April 2012 |
Contact: | Edwin E Spencer Jr, MD |
Email: | spencer9882@comcast.net |
Phone: | 865 450 1227 |
Two hundred patients will be analyzed both clinically (via validated outcomes measures) and
radiographically (via 2 sets of standard radiographs) to determine the survival and degree
of bone in growth of a novel all polyethelene glenoid component used in a standard FDA
approved shoulder arthroplasty system.
radiographically (via 2 sets of standard radiographs) to determine the survival and degree
of bone in growth of a novel all polyethelene glenoid component used in a standard FDA
approved shoulder arthroplasty system.
Methods and Materials: The standard of care in my practice and most practices is to have
arthroplasty patients return for an annual clinical and radiographic evaluation. We are
asking our patients that choose to enroll in the study to simply return for routine
"standard of care" follow up. The only deviation from this standard of care is the method by
which we obtain the xrays. In this study we will obtain true AP (anterior/posterior) and
axillary views on there return visit. These are our normal "standard of care" xrays. The
only difference is that we are going to obtain these Xrays using fluoroscopic guidance. The
reason we are using fluoroscopic guidance is that we want to make sure that the xrays are
perfect with the beam oriented tangential to the backside of the glenoid. This will allow us
to see any lucencies behind the glenoid and allow us to truly assess for any loosening.
Standard Xrays attempt to have the beam oriented tangential to the glenoid but just small
deviations can underestimate any potential lucent lines. This will expose the study subjects
to small amounts of radiation that would be outside the "standard of care". The patients
will be informed of this and the dose recorded. The fluoroscopy procedure will take about
15-20 minutes, but the total radiation exposure for the activities performed will be up to,
but not more than three minutes. The total radiation will be less than 3 rem. A licensed
radiology technologist (RT) employed by the hospital will perform the fluoroscopy procedures
and the Xrays. Jeff Jarnagin PA or Edwin Spencer MD will be present at all times during the
fluoroscopy procedure. Both Dr Spencer and Jeff Jarnagin have been involved in other similar
studies and have completed "training in human research subject protection". Subjects will be
provided proper shielding (lead apron) throughout the activities. The licensed radiology
technologist at the hospital will have the final responsibility for providing proper
shielding.
As with every clinical study, there may be some risks. Since the fluoroscope emits X-rays,
subjects will be exposed to radiation. During fluoroscopy, the actual dose of radiation
exposure that will be administered, is within minimal risk limits and will be much lower
than those known to produce detectable health effects. For this study, the fluoroscopy
machine will be on for up to, but not more than, 3 minutes total and the amount of radiation
will not exceed 3 rem which includes the radiation from the standard Xrays. According to
published literature, exposure risks below 5-10 rem are minimal. Health effects have not
been consistently demonstrated for radiation exposure below 10 rem.
Subjects will also fill out 2 data sheets. One is for the PENN score and the other is for
the ASES (Association of Shoulder and Elbow Surgeons) score which are validated clinical
outcomes measures. These forms are routinely filled out at their annual clinical visits and
are considered standard of care.
Data Analysis: The radiographs will be independently evaluated by 2 different board
certified radiologists blinded to the clinical results and names of the patients. The films
will be re-evaluated by each radiologist (they will be blinded to their initial reading) and
the average of their results will be recorded. The clinical ASES and PENN scores will be
recorded and differences in the preoperative and postoperative scores will be reported.
Statistical analysis such as a students t test is not necessary as we are not comparing two
groups however simple descriptive statistics will be used to report the change in ASES and
PENN scores and most importantly the presence or absence of lucent lines and location of any
lucencies. The lucent lines will be graded according to the method developed by Lazarus et
al.4 The medical records and Xray data will be kept as confidential as possible under
current local, state, and federal laws. The researchers will examine the medical records for
information related to both of the shoulders and the study data. The medical records that
identify the subject and the consent form will be reviewed by the researchers. The results
of this research project may be presented at meetings or in publications. The identity of
the subject will not be disclosed in any presentation or publication.
The Xrays will be stored in a secure place at the Knoxville Orthopaedic Clinic. These Xrays
will be accessible by only approved personnel. They will be kept indefinitely for the
possibility of future use in research or publications.
Personnel who will have access to your information include:
- Jeff Jarnagin PA (Assistant to Dr Spencer)
- Dr. Edwin Spencer, PI (Orthopaedic Surgeon)
Risk Analysis: The only risk involved is the extra amount of radiation required to obtained
the floroscopically guided Xrays. As stated above the maximum amount of radiation is 3 rem
which includes the radiation from the standard Xrays. According to published literature,
exposure risks below 5-10 rem are minimal. Health effects have not been consistently
demonstrated for radiation exposure below 10 rem. To protect the subjects a licensed
radiology technologist (RT) employed by the hospital will perform the fluoroscopy procedures
and the Xrays. Jeff Jarnagin PA or Edwin Spencer MD will be present at all times during the
fluoroscopy procedure. Subjects will be provided proper shielding (lead apron) throughout
the activities. The licensed radiology technologist at the hospital will have the final
responsibility for providing proper shielding.
The benefits to the patient is for the researchers (and readers of any published data) to
garner a better understanding of the best method to resurface the glenoid in a TSA. Many
patients require bilateral operations and therefore it could directly benefit a few patients
but essentially this project is designed to gather information for the greater good of all
patients who require a TSA.
Subject Identification, Recruitment And Consent: Subjects will be identified by a unique
identification number analogous to that used by the Knoxville Orthopaedic Clinic. Subjects
will be called by either Dr Edwin E Spencer Jr MD (PI) or his assistant Jeff Jarnagin PA and
asked to be involved or participate. The patients will be made aware that participation in
the study is completely voluntary and that participation does not affect their future access
to care by Dr Spencer. Informed consent will be reviewed over the phone and in person when
they come in for Xrays by Dr Spencer or his assistant Jeff Jarnagin PA. Attached is our
consent form. Once the subject has completed the xray evaluation and completed the clinical
forms, they will be paid the $50 stipend. The subject will incur no cost for participation
in the study. Insurance carriers will not be billed for any part of the study. The money for
the patients will come from the study sponsor DePuy Inc. The xrays including the floroscopy
and radiologists' readings will be paid for by the study sponsor DePuy. The surgeon, Dr
Spencer, will not be paid for his time and effort and is donating his time to science and
the greater good.
arthroplasty patients return for an annual clinical and radiographic evaluation. We are
asking our patients that choose to enroll in the study to simply return for routine
"standard of care" follow up. The only deviation from this standard of care is the method by
which we obtain the xrays. In this study we will obtain true AP (anterior/posterior) and
axillary views on there return visit. These are our normal "standard of care" xrays. The
only difference is that we are going to obtain these Xrays using fluoroscopic guidance. The
reason we are using fluoroscopic guidance is that we want to make sure that the xrays are
perfect with the beam oriented tangential to the backside of the glenoid. This will allow us
to see any lucencies behind the glenoid and allow us to truly assess for any loosening.
Standard Xrays attempt to have the beam oriented tangential to the glenoid but just small
deviations can underestimate any potential lucent lines. This will expose the study subjects
to small amounts of radiation that would be outside the "standard of care". The patients
will be informed of this and the dose recorded. The fluoroscopy procedure will take about
15-20 minutes, but the total radiation exposure for the activities performed will be up to,
but not more than three minutes. The total radiation will be less than 3 rem. A licensed
radiology technologist (RT) employed by the hospital will perform the fluoroscopy procedures
and the Xrays. Jeff Jarnagin PA or Edwin Spencer MD will be present at all times during the
fluoroscopy procedure. Both Dr Spencer and Jeff Jarnagin have been involved in other similar
studies and have completed "training in human research subject protection". Subjects will be
provided proper shielding (lead apron) throughout the activities. The licensed radiology
technologist at the hospital will have the final responsibility for providing proper
shielding.
As with every clinical study, there may be some risks. Since the fluoroscope emits X-rays,
subjects will be exposed to radiation. During fluoroscopy, the actual dose of radiation
exposure that will be administered, is within minimal risk limits and will be much lower
than those known to produce detectable health effects. For this study, the fluoroscopy
machine will be on for up to, but not more than, 3 minutes total and the amount of radiation
will not exceed 3 rem which includes the radiation from the standard Xrays. According to
published literature, exposure risks below 5-10 rem are minimal. Health effects have not
been consistently demonstrated for radiation exposure below 10 rem.
Subjects will also fill out 2 data sheets. One is for the PENN score and the other is for
the ASES (Association of Shoulder and Elbow Surgeons) score which are validated clinical
outcomes measures. These forms are routinely filled out at their annual clinical visits and
are considered standard of care.
Data Analysis: The radiographs will be independently evaluated by 2 different board
certified radiologists blinded to the clinical results and names of the patients. The films
will be re-evaluated by each radiologist (they will be blinded to their initial reading) and
the average of their results will be recorded. The clinical ASES and PENN scores will be
recorded and differences in the preoperative and postoperative scores will be reported.
Statistical analysis such as a students t test is not necessary as we are not comparing two
groups however simple descriptive statistics will be used to report the change in ASES and
PENN scores and most importantly the presence or absence of lucent lines and location of any
lucencies. The lucent lines will be graded according to the method developed by Lazarus et
al.4 The medical records and Xray data will be kept as confidential as possible under
current local, state, and federal laws. The researchers will examine the medical records for
information related to both of the shoulders and the study data. The medical records that
identify the subject and the consent form will be reviewed by the researchers. The results
of this research project may be presented at meetings or in publications. The identity of
the subject will not be disclosed in any presentation or publication.
The Xrays will be stored in a secure place at the Knoxville Orthopaedic Clinic. These Xrays
will be accessible by only approved personnel. They will be kept indefinitely for the
possibility of future use in research or publications.
Personnel who will have access to your information include:
- Jeff Jarnagin PA (Assistant to Dr Spencer)
- Dr. Edwin Spencer, PI (Orthopaedic Surgeon)
Risk Analysis: The only risk involved is the extra amount of radiation required to obtained
the floroscopically guided Xrays. As stated above the maximum amount of radiation is 3 rem
which includes the radiation from the standard Xrays. According to published literature,
exposure risks below 5-10 rem are minimal. Health effects have not been consistently
demonstrated for radiation exposure below 10 rem. To protect the subjects a licensed
radiology technologist (RT) employed by the hospital will perform the fluoroscopy procedures
and the Xrays. Jeff Jarnagin PA or Edwin Spencer MD will be present at all times during the
fluoroscopy procedure. Subjects will be provided proper shielding (lead apron) throughout
the activities. The licensed radiology technologist at the hospital will have the final
responsibility for providing proper shielding.
The benefits to the patient is for the researchers (and readers of any published data) to
garner a better understanding of the best method to resurface the glenoid in a TSA. Many
patients require bilateral operations and therefore it could directly benefit a few patients
but essentially this project is designed to gather information for the greater good of all
patients who require a TSA.
Subject Identification, Recruitment And Consent: Subjects will be identified by a unique
identification number analogous to that used by the Knoxville Orthopaedic Clinic. Subjects
will be called by either Dr Edwin E Spencer Jr MD (PI) or his assistant Jeff Jarnagin PA and
asked to be involved or participate. The patients will be made aware that participation in
the study is completely voluntary and that participation does not affect their future access
to care by Dr Spencer. Informed consent will be reviewed over the phone and in person when
they come in for Xrays by Dr Spencer or his assistant Jeff Jarnagin PA. Attached is our
consent form. Once the subject has completed the xray evaluation and completed the clinical
forms, they will be paid the $50 stipend. The subject will incur no cost for participation
in the study. Insurance carriers will not be billed for any part of the study. The money for
the patients will come from the study sponsor DePuy Inc. The xrays including the floroscopy
and radiologists' readings will be paid for by the study sponsor DePuy. The surgeon, Dr
Spencer, will not be paid for his time and effort and is donating his time to science and
the greater good.
Inclusion Criteria: all patients with standard OA who had a shoulder arthroplasty with an
anchor peg glenoid -
Exclusion Criteria:Any paient who had a concomitant rotator cuff tear, infection, revision
or previous arthroplasty.
We found this trial at
1
site
Click here to add this to my saved trials