Acute Optimization of Cardiac Resynchronization Therapy (CRT)Using Echocardiography and SonR



Status:Completed
Conditions:Cardiology
Therapuetic Areas:Cardiology / Vascular Diseases
Healthy:No
Age Range:18 - Any
Updated:11/22/2017
Start Date:February 2011
End Date:June 2014

Use our guide to learn which trials are right for you!

Acute Optimization of Cardiac Resynchronization Therapy (CRT) Using Echocardiography and SonR

The purpose of this study is to correlate the three lead placement (wires that go to the
heart) possibilities and the responses from the patient's heart. This will be done with the
help of an echocardiography and SonR signals, which is an external device that is capable of
detecting sounds created by the heart.

A cardiac resynchronization therapy defibrillator (CRT-D) is a device designed to
automatically recognize and stop rapid, harmful heart beats and allow the heart to return to
a safe, regular heart rhythm. The CRT-D device may help the heart pump more efficiently by
improving the timing of different parts of the heart beat. A CRT-D device has three leads
(wires that go to the heart). One lead is placed in one of the top chambers of the heart
(right atrium), another lead is placed in the lower right chamber (right ventricle) and the
third lead is placed along the side of the left ventricle. The top chambers are stimulated
first, either by the natural heartbeat or by the CRT-D device if the heartbeat is too slow.
Shortly after that, the bottom chambers are stimulated. By pacing the heart in this way, the
doctor hopes to improve the timing of different components of the heart beat in order to
improve the efficiency of the heart and to improve the patient's heart failure symptoms. The
purpose of this study is to correlate the three lead placement possibilities and the
responses from the patient's heart. This will be done with the help of an echocardiography
and SonR signals, which is an external device that is capable of detecting sounds created by
the heart.

Based on the CRT implant, special measurements will be made to optimize the placements of the
device leads. Based on the success of those measurements and a patient's own response, the
patient will be placed into one of three groups.

Group 1: Patients with no response

Patients with a successful response will be randomized to:

Group 2: Lead placement based on study measurements

OR

Group 3: Standard lead placement

Inclusion Criteria:

- Must have been indicated for implantation or upgrade to a CRT-D system in the last 3
months

- Indicated for CRT according to current guidelines

- QRS Duration between 120 ms and 150 ms

- Able and willing to provide consent and Authorization of Use of PHI

Exclusion Criteria:

- Myocardial infarction or acute coronary syndrome deemed inappropriate for trial per
the investigator within 90 days of implant

- Planned, or recent heart surgery or revascularization within the last three months

- Already enrolled in other study that precludes enrollment in this study per Principal
Investigator

- Known Pregnancy at the time of enrollment

- Age less than 18 at the time of enrollment

- Unable to comply with follow-up requirements

- Chronic Atrial Fibrillation

- Recent history of medical non-compliance as determined by the investigator

- Unable or unwilling to provide consent and Authorization of Use of PHI