A Comparison of Methods for Assisting Needle Angle Selection During Image-guided Tissue Biopsy



Status:Completed
Conditions:Lung Cancer, Liver Cancer, Cancer, Cancer
Therapuetic Areas:Oncology
Healthy:No
Age Range:18 - 100
Updated:3/24/2019
Start Date:September 20, 2010
End Date:November 16, 2016

Use our guide to learn which trials are right for you!

A Comparison of Methods for Assisting Needle Angle Selection During Image-Guided Tissue Biopsy

Background:

- Currently, standard procedures for biopsies that are guided by computed tomography (CT)
imaging involve CT scans and a computer program to plan and illustrate where the physician
will place the needle to obtain the required cells or tissue. Inserting the biopsy needle at
the planned angle is not an easy task, because the appropriate angle of insertion must be
estimated based on prior experience. Researchers are studying experimental techniques that
might provide better guidance about the right angle to insert the biopsy needle and thereby
improve the collection of the appropriate biopsy cells or tissue.

Objectives:

- To evaluate the effectiveness of two biopsy needle guidance methods in CT-guided tissue
biopsy.

Eligibility:

- Individuals at least 18 years of age who are scheduled to have CT-guided tissue biopsy.

Design:

- Participants will have a tissue biopsy guided by CT scans and either a laser system or a
plastic block to illustrate the appropriate angle of insertion. The skin will be numbed
with anesthetic to minimize discomfort during the procedure.

- Before inserting the biopsy needle, the study physician will hold the needle in place so
that a Food and Drug Administration-approved medical GPS (electromagnetic tracking)
system can measure the needle angle as it enters the tissue.

- After the needle angle data has been collected, researchers will proceed with the actual
biopsy procedure as it would normally occur, using standard methods.

- No additional treatment will be provided as part of this protocol.

Background:

- Currently, standard/conventional CT-guided biopsies proceed as follows the physician:

1. obtains a pre-procedural CT scan,

2. plans the needle s angle based on this CT scan,

3. selects the angle at which the needle should be inserted based on the
pre-procedural CT scan,

4. inserts the needle while aiming to replicate that planned needle angle by using
only their visual-spatial abilities, and

5. re-images the patient to confirm needle location followed by needle

repositioning, if needed.

- Improving upon these standard methods of needle placement could have

widespread benefits (e.g. improved diagnostic tissue sampling, decreased

needle repositionings, etc.) We will be studying three needle angle selection systems. The
laser-assisted needle angle selection system or LNASS, is a custom fabricated device that
uses a Class II pointer similar to ones used for pointing at slides during lectures.

Objectives:

- To compare the angle difference between L-NASS (Method A) and the standard method
(clinician intuition/conventional method)

- To compare the angle difference between B-NASS (Method B) and the standard method
(clinician intuition)

- To compare the angle difference between the mobile device-NASS or MD-NASS (C) and the
standard method (clinician intuition/conventional method)

Eligibility:

- Ages Eligible for Study: 18 Years and older

- Genders Eligible for Study: Both

- Inclusion:

- Must be undergoing a scheduled CT-guided biopsy.

- Must have ability to follow breathing instructions like holding breath (if
procedure is to be performed without general anesthesia).

- Exclusion:

- No serious concurrent medical illness that would preclude the patient from making a
rational informed decision on participation.

- Any known allergy to plastics or polymers (since the Ultem polymer could theoretically
induce a rash in these patients, even though it is hypoallergenic).

- Pacemakers or automatic implantable cardiac defibrillators.

- Gross body weight above the CT table limit (450 pounds).

Design:

- Primary outcome measure for the first arm is:

--The difference between planned and achieved needle angle of a laser-assisted needle
angle selection system with the standard method (clinician s intuition or conventional
method) of CT-guided biopsy.

- Primary outcome measure for the second arm is:

--The difference between planned and achieved needle angle of a block with pre-drilled
needle angles with the standard method (clinician s intuition or conventional method) of
CT-guided biopsy

- Primary outcome for the third arm is:

--The difference between planned and achieved needle angle of a mobile device-assisted
needle angle selection system with the standard method (clinician's intuition or
conventional method) of CT-guided biopsy.

- The tool for measuring the needle angles will be an FDA-approved electromagnetic
tracking system, which tracks needle movement and position.

- These comparisons will be done as a bystander study.

- Needle guidance system will only be used initially to select the angle during a
superficial, shallow needle insertion at the skin surface (less than 1 cm deep).

- At no time will the needle enter tissue that it wouldn t have otherwise entered as none
of the system will be used to perform the biopsies at this time.

- The key portions of the procedure will not be altered in any substantive way.

- INCLUSION CRITERIA:

Patients must fulfill all of the following criteria to be eligible for study admission:

- All patients must be undergoing a CT-guided biopsy.

- Age greater than 18 years.

- No serious concurrent medical illness that would preclude the patient from making a
rational informed decision on participation.

- The ability to understand and willingness to sign a written informed consent form, and
to comply with the protocol. If in question, an ethics consult will be obtained.

- Ability to follow breathing instructions like holding breath (if procedure is to be
performed without general anesthesia).

- Patients must be actively enrolled on an NIH protocol and be scheduled for a CT-guided
biopsy.

EXCLUSION CRITERIA:

- Patients with an altered mental status that precludes understanding or consenting for
the biopsy procedure will be excluded from this study.

- Patients unlikely to be able to hold reasonably still on a procedure table for the
length of the procedure.

- Patients with any known allergy to plastics or polymers (since the Ultem -polymer
could theoretically induce a rash in these patients, even though it is
hypoallergenic).

- Inability to follow breathing instructions, if without general anesthesia.

- Patients with pacemakers or automatic implantable cardiac defibrillators.

- Gross body weight above the CT table limit (450 pounds).