Transurethral Ultrasonic Imaging For Detection and Classification of Prostate Cancer



Status:Completed
Conditions:Prostate Cancer, Cancer
Therapuetic Areas:Oncology
Healthy:No
Age Range:40 - 80
Updated:4/2/2016
Start Date:June 2013
End Date:December 2015
Contact:Thomas E Ahlering, MD
Email:tahlering@uci.edu
Phone:714-456-6068

Use our guide to learn which trials are right for you!

This study is being performed to verify the ability to use minimally invasive transurethral
ultrasonic imaging technology for the purpose of identifying prostate cancer. Transurethral
ultrasonic prostate imaging, may in the future, be used for detection and monitoring these
disease processes to minimize the need for obtaining surgical biopsy specimens. The
hypothesis is that tissue-density variations, as revealed in diagnostic ultrasonic imaging,
results in unique image signatures for identification of prostate cancer. This imaging
procedure provides a multifaceted view of the entire in-situ gland.

The current use of Prostate Specific Antigen (PSA) for determining the likelihood of
presence of cancer in the prostate gland requires interpretation and has a good but limited
to predict prostate cancer on biopsy, with significant false prediction rates. More
importantly as a blood test, the PSA test lacks the ability to pinpoint the location of the
cancer within the prostate gland. Preliminary study findings have suggested that
"Transurethral Ultrasonic Scanning" (TUUS) presents the desired improved diagnostic
sensitivity for detection of cancer within the imaged prostate gland, and has the intrinsic
capability to provide high resolution images of the transverse and future three-dimensional
views of the entire gland better than currently used Transurethral Ultrasound (TRUS). Two
important goals of the practicality of this minimally invasive technology will be assessed
by this study. 1. The ability of TUUS to directly detect prostate cancer locations in the
prostate. 2. The use of TUUS to successfully guide the prostate needle biopsy to cancer loci
with a high rate accuracy.

The Purpose of the Research The primary objective of this Institutional Review
Board-controlled study is to determine if the presently manually-read results of TUUS data
obtained with the novel UreScan device can be correlated with pathologist findings in a
harvested prostate gland from an individual with diagnosed prostate disease. If successful,
a future Institutional Review Board study will explore the use of computer software to
examine the 256 transverse image slices of a large number of prostate cancer patients to
establish the clinical applicability of TUUS for screening and assessment of individuals
with elevated levels of PSA and/or positive digital rectal examinations (DRE), potentially
reducing the number of future biopsy examinations with false-positive findings.

Background Information The current use of Prostate Specific Antigen for determining the
likelihood of presence of cancer in the prostate gland has been shown to be seriously
flawed. Multiple studies reviewing the findings of referred biopsies, based on elevated PSA
levels, resulted in as many as 70% false positive findings for cancer. Improved rapid,
minimally-invasive, low-cost methodology and technology should be developed to provide
diagnostic cancer findings that have higher sensitivity and specificity is the objective
goal of the present research. Preliminary study findings have suggested that "Transurethral
Ultrasonic Scanning" (TUUS) presents the desired improved diagnostic sensitivity for
detection of cancer within the imaged prostate gland and has the intrinsic capability to
provide high resolution images of the transverse and future three-dimensional views of the
entire gland. Two important goals of this minimally invasive technology will be assessed by
this study. 1. The ability of TUUS to directly detect prostate cancer in situ in the
prostate. 2. The use of TUUS to successfully guide the prostate needle biopsy to cancer loci
with a high rate accuracy.

In a 2003 study by Holmes et al, the TUUS device was tested on 2 patients who had seeds
implanted for prostate cancer. TUUS revealed more seeds (82%, 84%) than standard TRUS (63%,
65%) in the 2 patients. These simple cases demonstrated the feasibility of providing
transverse images of the entire prostate gland. Holmes postulated that this procedure would
have to be automated to achieve any clinical utility value and the project essentially was
abandoned by Mayo.

The TUUS/"UreScan" system is a marriage of an off label usage of the FDA approved vascular
probe, placed inside a standard foley catheter which is inserted into the penis onto the
prostate to the neck of the bladder. The ultrasound probe travels the length of the prostate
(~4-8cm) within the sheath of the catheter and images the entire prostate with ultrasound.
The travel of the ultrasound probe is controlled by a small motor which is driven from
outside the catheter and patient as well. This motor driven probe offers the possibility of
accurate and reproducible ultrasounds of the prostate, as the patient's prostate apex is
used the anchor point for study.

Refinements to the TUUS system include:

1. A Foley type introducer should be used for placing the intravascular ultrasound
transducer in the prostatic urethral region to be imaged

2. Use of a fixed-position, ultrasonic coupling gel-coated Introducer to eliminate the
possibility of urethral abrasion or trauma as might otherwise occur without the
Introducer when moving the transducer within the prostatic imaging region.

3. Insertion into the Introducer of the wire-rotationally-driven ultrasonic transducer as
coated with sterile water ultrasonic coupling between the transducer and introducer

4. The examiner would then initiate the automated scanning procedure with analog/digital
video data for each of 256 transverse axial image slices of the prostate gland. The
scanning of the gland can be stopped or started at the election of the examiner

5. A video-media record of the images derived from the procedure is available to an
experienced reader for interpretation.

The initial UreScan hydrophone verified specifications included: 1. 256 transverse,
automatically axially advanced, image slices. 2. Approximately 267 megabits of video data.
3. Diagnostic ultrasound scanning of 100 revolutions per minute at 9.0 M Megahertz. 4.
Radial penetration of 6 cm. The scanner features:

1. The amplitude of reflected ultrasonic echoes from biological tissue, as displayed by a
density-based oscillogram is directly proportional to the density of the tissue being
insonated in an adjusted flat far-gain ultrasonic system.

2. Longitudinal time-related, ultrasonic densitometry and image-registered comparisons of
sonograms have demonstrated progression and/or regression of disease consistent with
efficacy of treatment procedures. This facilitates future "wait and watch surveillance"
of known or suspected lesions while potentially minimizing and/or eliminating
unnecessary surgical biopsy tissues procedures

3. The reflected echo waveform and sonogram has been shown to be unique for each type of
disease entity. In prostate disease, there is a unique difference between the
image-markers for prostate cancer and normal tissue.

The present study protocol is to determine if image-markers for cancer and other unique
prostate pathology can be specifically identified. Further clinical studies will be required
to determine sensitivity, specificity, accuracy and (+/-) predictor values of this
procedure. Additional studies will be required to determine if the amplitude of the
image-markers could be used for determining the approximate stage of the image detected
disease processes.

Inclusion Criteria:

- Men undergoing a standard of care radical prostatectomy for prostate cancer.

- Aged > 40 years old.

- Men who have a serious prostate obstruction, are excluded due to the difficulty of
catheter insertion.

Exclusion Criteria:

- Women are excluded as they do not have a prostate gland.

- Minors are excluded as prostate cancer is generally found only in men aged > 40 years
old
We found this trial at
1
site
501 East Peltason Drive
Orange, California 92868
?
mi
from
Orange, CA
Click here to add this to my saved trials