Endotracheal Tube Audible Leak Test



Status:Recruiting
Healthy:No
Age Range:Any - 8
Updated:4/21/2016
Start Date:June 2015
End Date:June 2016
Contact:Madhankumar Sathyamoorthy, MBBS, MS
Email:msathyamoorthy@umc.edu
Phone:601-815-7066

Use our guide to learn which trials are right for you!

Endotracheal Tube Audible Leak Test: What is the Accuracy?

The endotracheal tube (ETT) leak test (LT), or audible leak test is a widely performed
assessment to verify appropriate tube size in neonates, infants and children. However, many
factors are known to influence the audible leak test. Even though the test is widely
performed, the accuracy has not been evaluated.

The endotracheal tube (ETT) leak test (LT), or audible leak when the peak airway pressures
reach 15-30 cmH2O, is a commonly performed assessment to confirm that an endotracheal tube
size is appropriate for a child in order to minimize the risk of airway injury and adverse
events after removal of ETT. Many factors are known to affect the results of the leak test
and variation in results among experienced anesthesiologists may be as great as 38%, but the
accuracy of the audible leak test by directly observing the presence of a leak around the
ETT has not been evaluated. This study will attempt to use direct visualization of the air
leak to correlate to and assess the accuracy of the audible air leak test.

Inclusion Criteria:

- Children aged between 1 month (post-natal) and 8 years scheduled for ENT surgery
requiring general anesthesia with an endotracheal tube.

Exclusion Criteria:

- Known history of subglottic stenosis

- Known history of recurrent croup

- Known history of endolaryngeal or subglottic lesions

- Parents refusal of participation in study
We found this trial at
1
site
2500 N State St
Jackson, Mississippi 39216
(601) 984-1000
University of Mississippi Medical Center The University of Mississippi Medical Center, located in Jackson, is...
?
mi
from
Jackson, MS
Click here to add this to my saved trials