Medtronic Transcatheter Aortic Valve Replacement (TAVR) Low Risk Bicuspid Study



Status:Recruiting
Conditions:Cardiology
Therapuetic Areas:Cardiology / Vascular Diseases
Healthy:No
Age Range:65 - Any
Updated:1/9/2019
Start Date:December 20, 2018
End Date:December 2030
Contact:Hatice Bilgic Lim, PhD
Email:hatice.bilgic.lim@medtronic.com
Phone:763-526-1018

Use our guide to learn which trials are right for you!

Transcatheter Aortic Valve Replacement (TAVR) With Medtronic TAVR System in Patients With Severe Bicuspid Aortic Valve Stenosis and at Low Predicted Risk of Mortality With Surgical Aortic Valve Replacement (SAVR)

The objective of the trial is to evaluate the procedural safety and efficacy of the Medtronic
TAVR system in patients with bicuspid aortic anatomy and severe aortic stenosis at low risk
for SAVR

Multi‐center, prospective, single arm

All subjects will be treated with a Medtronic TAVR system. Subject follow-ups will be
conducted at pre and post-procedure, discharge, 30 days, 1 year, and annually through 10
years

Inclusion Criteria:

1. Severe aortic stenosis, defined as follows:

1. For symptomatic patients:

Aortic valve area ≤1.0 cm2 (or aortic valve area index of ≤0.6 cm2/m2), OR mean
gradient ≥40 mmHg, OR Maximal aortic valve velocity ≥4.0 m/sec by transthoracic
echocardiography at rest

2. For asymptomatic patients:

Very severe aortic stenosis with an aortic valve area of ≤1.0 cm2 (or aortic valve
area index of ≤0.6 cm2/m2), AND maximal aortic velocity ≥5.0 m/sec, or mean gradient
≥60 mmHg by transthoracic echocardiography at rest, OR

Aortic valve area of ≤1.0 cm2 (or aortic valve area index of ≤0.6 cm2/m2), AND a mean
gradient ≥40 mmHg or maximal aortic valve velocity ≥4.0 m/sec by transthoracic
echocardiography at rest, AND an exercise tolerance test that demonstrates a limited
exercise capacity, abnormal BP response, or arrhythmia OR

Aortic valve area of ≤1.0 cm2 (or aortic valve area index of ≤0.6 cm2/m2), AND mean
gradient ≥40 mmHg, or maximal aortic valve velocity ≥4.0 m/sec by transthoracic
echocardiography at rest, AND a left ventricular ejection fraction <50%.

2. Patient is considered low risk for SAVR, where low risk is defined as predicted risk
of mortality for SAVR <3% at 30 days per multidisciplinary local heart team
assessment.

3. Bicuspid aortic valve anatomy (all sub‐types) confirmed by MDCT.

4. The subject and the treating physician agree that the subject will return for all
required post‐procedure follow‐up visits.

Exclusion Criteria:

1. Any condition considered a contraindication for placement of a bioprosthetic valve
(eg, subject is indicated for mechanical prosthetic valve).

2. Age less than 65 years

3. A known hypersensitivity or contraindication to any of the following that cannot be
adequately pre-medicated:

1. aspirin or heparin (HIT/HITTS) and bivalirudin

2. ticlopidine and clopidogrel

3. Nitinol (titanium or nickel)

4. contrast media

4. Blood dyscrasias as defined: leukopenia (WBC <1000 mm3), thrombocytopenia (platelet
count <50,000 cells/mm3), history of bleeding diathesis or coagulopathy, or
hypercoagulable states.

5. Ongoing sepsis, including active endocarditis.

6. Any percutaneous coronary or peripheral interventional procedure with a bare metal
stent or drug eluting stent performed within 30 days prior to screening committee
approval.

7. Multivessel coronary artery disease with a Syntax score >22 and/or unprotected left
main coronary artery.

8. Symptomatic carotid or vertebral artery disease or successful treatment of carotid
stenosis within 10 weeks of Heart Team assessment.

9. Cardiogenic shock manifested by low cardiac output, vasopressor dependence, or
mechanical hemodynamic support.

10. Recent (within 2 months of Heart Team assessment) cerebrovascular accident (CVA) or
transient ischemic attack (TIA).

11. Gastrointestinal (GI) bleeding that would preclude anticoagulation.

12. Subject refuses a blood transfusion.

13. Severe dementia (resulting in either inability to provide informed consent for the
study/procedure, prevents independent lifestyle outside of a chronic care facility, or
will fundamentally complicate rehabilitation from the procedure or compliance with
follow-up visits).

14. Estimated life expectancy of less than 24 months due to associated non-cardiac
co-morbid conditions.

15. Other medical, social, or psychological conditions that in the opinion of the
investigator precludes the subject from appropriate consent or adherence to the
protocol required follow-up exams.

16. Currently participating in an investigational drug or another device study (excluding
registries).

17. Evidence of an acute myocardial infarction ≤30 days before the study procedure due to
unstable coronary artery disease (WHO criteria).

18. Need for emergency surgery for any reason.

19. Subject is pregnant or breast feeding.

20. Subject is legally incompetent, or otherwise vulnerable

Anatomical exclusion criteria:

21. Pre-existing prosthetic heart valve in any position.

22. Severe mitral regurgitation amenable to surgical replacement or repair.

23. Severe tricuspid regurgitation amenable to surgical replacement or repair.

24. Moderate or severe mitral stenosis amenable to surgical replacement or repair.

25. Hypertrophic obstructive cardiomyopathy with left ventricular outflow gradient.

26. Prohibitive left ventricular outflow tract calcification.

27. Sinus of Valsalva diameter unsuitable for placement of the self-expanding
bioprosthesis

28. Aortic annulus diameter of <18 or >30 mm.

29. Significant ascending aortopathy requiring surgical repair

30. Ascending aorta diameter > 4.0 cm

For transfemoral or transaxillary (subclavian) access:

31. Access vessel mean diameter <5.0 mm for Evolut 23R, 26R, or 29R mm TAV, or access
vessel mean diameter <5.5 mm for Evolut 34R mm or Evolut PRO 23R, 26R, 29 R mm TAV.
However, for transaxillary (subclavian) access in patients with a patent LIMA, access
vessel mean diameter <5.5mm for Evolut 23R, 26R, or 29R mm TAV, or access vessel mean
diameter <6.0 mm for the Evolut 34R or Evolut PRO TAV.
We found this trial at
8
sites
Columbus, Ohio 43214
Principal Investigator: Steven Yakubov, MD
?
mi
from
Columbus, OH
Click here to add this to my saved trials
1111 6th Ave
Des Moines, Iowa 50314
(515) 247-3121
Principal Investigator: Atul Chawla, MD
Mercy Medical Center - Des Moines Mercy Medical Center
?
mi
from
Des Moines, IA
Click here to add this to my saved trials
9981 South Healthpark Drive
Fort Myers, Florida 33908
Principal Investigator: Brian Hummel, MD
?
mi
from
Fort Myers, FL
Click here to add this to my saved trials
111 South Front Street
Harrisburg, Pennsylvania 17101
Principal Investigator: Hemal Gada, MD
?
mi
from
Harrisburg, PA
Click here to add this to my saved trials
800 E 28th St
Minneapolis, Minnesota 55407
(612) 863-4000
Principal Investigator: Mario Goessl, MD
Abbott Northwestern Hospital Our hospital has a long and proud history as a health care...
?
mi
from
Minneapolis, MN
Click here to add this to my saved trials
Roslyn, New York 11576
Principal Investigator: George Petrossian, MD
?
mi
from
Roslyn, NY
Click here to add this to my saved trials
Thousand Oaks, California 91360
Principal Investigator: Dev Vishva, MD
?
mi
from
Thousand Oaks, CA
Click here to add this to my saved trials
Winchester, Virginia 22604
Principal Investigator: Basel Ramlawi, MD
?
mi
from
Winchester, VA
Click here to add this to my saved trials